00131918_0
Universalregler VRD3


00131918_0

Dynamic differential pressure transducers

For the dynamic measurement of effective and differential pressures

Differential pressure transducers based on the dynamic measurement principle for volume flow rate measuring units Type VMR or VME

  • Linear volume flow rate actual value 0 – 10 V DC or 2 – 10 V DC
  • Recording of measured values for the display of volume flow rates or for the control of slave controllers
  • Any installation orientation
  • Parameters are factory set

Application

Application

  • Electronic volume flow controller Universal with dynamic differential pressure transducer for use with volume flow rate measuring units
  • Parameters are factory set
  • On-site adjusting is not required

Standard filtration in comfort air conditioning systems allows for use of the transmitter in the supply air without additional dust protection. Since a partial volume flow is passed through the differential pressure transducer in order to measure the volume flow rate, please note:

  • With heavy dust levels in the room, suitable extract air filters must be provided.
  • If the air is polluted with fluff or sticky particles, or if it contains aggressive media, dynamic pressure transducers cannot be used

For this application the Universal controller is only used for measuring the differential pressure and for transforming the measured value into a linear voltage signal. Connections for setpoint value signal and actuator are not relevant, and neither are the corresponding technical data.

  • Volume flow rate actual value is available as linear voltage signal

Description

Parts and characteristics

  • Sensor for dynamic differential pressure measurements

Technical information

Function, Technical data, Produktbeziehungen

  • FUNCTION
  • TECHNICAL DATA
Principle of operation – dynamic differential pressure transducer 00133062_0
① Differential pressure transducer
② Volume flow controller
③ Actual value signal


Functional description

The volume flow rate is determined by measuring the effective pressure. For this reason the measuring unit is fitted with an effective pressure sensor.

The integral differental pressure transducer transforms the effective pressure into a voltage signal. The volume flow rate actual value is hence available as a voltage signal. The factory setting is such that 10 V DC always corresponds to the nominal volume flow rate (Vnom).

Voltage ranges are factory stored in the controller. Changes on the customer's site can easily be carried out using an adjustment device or a notebook with service tool.

Volume flow controller VRD3

Supply voltage (AC)

24 V AC ± 20 %, 50/60 Hz

Supply voltage (DC)

24 V DC −10/+20 %

Power rating (AC)

without actuator max. 3.5 VA

Power rating (DC)

without actuator max. 2 W

Setpoint value signal input

0 – 10 V DC, Ra > 100 kΩ

Actual value signal output

0 – 10 V DC, 0.5 mA max.

IEC protection class

III (protective extra-low voltage)

Protection level

IP 40

EC conformity

EMC according to 2014/30/EU

Weight

0.440 kg


Variants

  • Variants
Universal controller VRD3 00131918_0


Any attachments are to be defined with the order code of the volume flow rate measuring unit.

B10

Application

  • Electronic volume flow controller VRD3 with dynamic differential pressure transducer for use with volume flow rate measuring units
  • Differential pressure transducer and controller electronics are fitted together in one casing

Signal voltage range

  • 0: 0 – 10 V DC
  • 2: 2 – 10 V DC

Parts and characteristics

  • Sensor for dynamic differential pressure measurements

Dynamic differential pressure transducers for volume flow rate measuring units

Order code detail Attachment Controller Volume flow rate measuring unit
Order code detail Part number Type

B10

M546GA4

VRD3

VMR, VME


Electrical connection, Characteristics

  • ELECTRICAL CONNECTION
  • CHARACTERISTICS
B1*, Klemmenbelegung 00135380_0
① Steckverbindung Stellantrieb
② Steckverbindung Einstellgerät
1 ⊥, –: Masse, Null
2 ~, +: Versorgungsspannung
3 w: Sollwertsignal
4 PP: Anschluss Einstellgerät
5 U5: Istwertsignal
6 z1: Zwangssteuerung 1 (AUF)
7 z2: Zwangssteuerung 2 (ZU, Vmin, Vmax)

Universal: VRD3

Downloads

product information

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +44 (0)1842 754545 | Fax: +44 (0)1842 763051

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +44 (0)1842 754545 | Fax: +44 (0)1842 763051

Contact

We are here for you

Please specify your message and type of request.
Tel.: +44 (0)1842 754545 | Fax: +44 (0)1842 763051

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +44 (0)1842 754545 | Fax: +44 (0)1842 763051